FOR RESEARCH USE ONLY
96 determinations
Purpose
This kit allows for the determination of ORFV Ab ex
Principle of the assay
The kit assay ORFV Ab level in the sample,use Purified antigen to coat microtiter plate wells, make solid-phase antigen, then add ORFV Ab to wells, Combined With ORFV Ab, after washing and removing non-combinative antigen and other compo
Materials provided with the kit
1 wash solution 20ml×1bottle 7 Stop Solution 6ml×1 bottle
2 HRP-Co
3 Microelisa stripplate 12well×8strips 9 Negative co
4 Sample diluent 6ml×1 bottle 10 Instruction 1
5 Chromogen Solution A 6ml×1 bottle 11 Closure plate membrane 2
6 Chromogen Solution B 6ml×1 bottle 12 Sealed bags 1
Specimen requirements
1.extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
2.Can’t detect the sample which co
Assay procedure
1.Number: to sample correspond microtitration well and Number Sequence, each plate should be set feminine comparison 2 wells, masculine comparison 2 wells, blank comparison 1 well(don’t add sample and HRP-Co
2.add sample:separately add Positive co
3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃.
4.Co
5.washing:Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
6.add enzyme:Add HRP-Co
7.incubate:Operation with 3.
8.washing:Operation with 5.
9.color:Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37℃
10.Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
11. assay:take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.
Determine the result
Test validity: the average of Positive co
Calculate Critical(CUT OFF) : Critical= the average of Negative co
Negative control: sample OD< Calculate Critical(CUT OFF) is ORFV Ab Negative control.
Positive control: ample OD≥ Calculate Critical(CUT OFF) is ORFV Ab Positive control.
im
1.Please according to use instruction strictly, Do not mix reagents with those from other lots.
2.The kit takes out from the refrigeration enviro
3.washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
4.Closure plate membrane o
5.The substrate please evade the light preservation.
6.The test result determination must take the microtiter plate reader as a standard, when use dual-wavelength to assay, Reference wavelength is 630nm.
7.All samples, washing buffer and each kind of reject should according to infective material process. Stopp Solution is 2M sulphuric acid. You must pay attention to safe when use .
Storage and validity
1.Storage: 2-8℃.
2.validity: six months.
http://www.yi7.com/com_fsdfhskdj/





