Features & Benefits
The H-10G detects all CFC HFC and HCFC Refrigerants
Manual zero balance control
Unique sensor balance system
Pinpoints both small and large leaks
AC powered
Switchable sensitivity
25 years of proven experience
Certified to SAEJ1627
CE Mark
Specifications
Detects: All CFC HFC and HCFC Refrigerants
Sensing Element: Positive Ion Emission Heated Diode
Sensitivity: Moving probe test per SAE Std. J1627
Alarm Sensitivity:
R-134a
Moving Probe
Small - 0.5 oz/year
Medium - 1.0 oz/year
Large - 5.0 oz/year
Stationary Probe
Small - 0.1 oz/year
Medium - 0.5 oz/year
Large - 2.0 oz/year
R-12
Small - 0.1 oz/year
Medium - 0.5 oz/year
Large - 3.0 oz/year
Warm-Up Time: Approx. 2 minutes
Accuracy: Exceeds SAE J1627
Probe Length: 4.5 feet
Dimensions: 2.5" x 4.5" x 8.5"
Weight: Approx. 3 lbs
Agency Listings: UL file SA9717 SAE J1627 (exceeds capability but is not listed)
Power: 120 VAC 50/60 Hz (optional 220/230/240 VAC)
Leak Alarm: Audible alarm and visible neon lamp
Response Time: Approx. 1 sec.