当前位置:给览网 » 供应 » 仪器配件 » 色谱柱 » 浩瀚色谱(山东)应用技术开发有限公司 » 色谱柱

联系我们

公司名称:浩瀚色谱(山东)应用技术开发有限公司

联系人:王经理

电话:0632-5667636

手机:15562228838(微信同号)13963221227(微信同号)

传真:0632-5667636

邮件:1404939462@qq.com

地址:山东省滕州市(市场部和技术部);

会员站:http://www.haohansepuyi.com

产品详情

GDX-502 气体自动进样器测定气体中非甲烷总烃

  • 产品/服务:GDX-502 气体自动进样器测定气体中非甲烷总烃
  • 型 号:GDX-502
  • 品 牌:浩瀚色谱
  • 单 价:面议 
  • 更新日期:2021-05-16
  • 有效期至:长期有效
  • 浏览次数:1196
产品简介

气体自动进样器测定气体中非甲烷总烃,液化石油气,二甲醚,甲醇,甲酸,粗苯,三苯,植物油,6号溶剂残留,脂肪酸,甲醛,硫化物...

产品详细介绍
气体自动进样器测定气体中非甲烷总烃
气体自动进样器测定气体中非甲烷总烃 详细信息:

固定相:高分子小球

GDX-502,2m*3mm,2m*4mm,2m*1/8,60-80目

甲烷柱


总烃柱

2m*3mm,2m*4mm,2m*1/8,硅烷化玻璃微球

非甲烷总烃测定多采用针筒或气袋采集样品、手工进样的方式测试非甲烷总烃。该操作过程较频繁、耗时长,且人为造成的误差也较大。

滕州市浩瀚色谱仪器技术服务有限公司,采用自动进样和气体分流技术,双柱双FID检测器气相色谱法测定气体中的非甲烷总烃,实现了非甲烷总烃的连续自动分析,同时一次进样即可得到甲烷和总烃的数据。方法的检出限为0.05 mg/m3,测定的相对标准偏差在0.7%~1.8%内,非甲烷总烃的加标回收率为96.0%~98.5%。与传统手动进样法相比,本方法具有重复性好、操作简单、省时等优点,可大大提高气体中非甲烷总烃的分析效率和准确度。


气体自动进样器测定气体中非甲烷总烃 图片:


Determination of non-methane total hydrocarbons in gases by gas autosampler
Gas autosampler for the determination of non-methane total hydrocarbons in gases Details:

Stationary phase: polymer pellet
GDX-502, 2m*3mm, 2m*4mm, 2m*1/8, 60-80 mesh
Methane column

Total hydrocarbon column
2m*3mm, 2m*4mm, 2m*1/8, silanized glass microspheres

For the determination of non-methane total hydrocarbons, samples of syringes or air bags are used to collect samples, and non-methane total hydrocarbons are tested by manual injection. This operation process is frequent, time consuming, and human error is also large.

Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. uses automatic injection and gas splitting technology, two-column dual FID detector gas chromatography to determine non-methane total hydrocarbons in gas, and achieves continuous automatic analysis of non-methane total hydrocarbons. The injection can be used to obtain data on methane and total hydrocarbons. The detection limit of the method was 0.05 mg/m3, and the relative standard deviation of the method was 0.7%~1.8%. The recoveries of non-methane total hydrocarbons were 96.0%~98.5%. Compared with the traditional manual injection method, the method has the advantages of good repeatability, simple operation, time-saving and high efficiency, and can greatly improve the analysis efficiency and accuracy of non-methane total hydrocarbons in the gas.


Determination of non-methane total hydrocarbons in gases by a gas autosampler


如果您觉得“GDX-502 气体自动进样器测定气体中非甲烷总烃”描述资料不够齐全,请联系我们获取详细资料。(联系时请告诉我从给览网看到的,我们将给您最大优惠!)
本页链接:http://www.geilan.com/com_haohanyiqi/sell/itemid-8707987.html
已经有1196位访客查看了本页.
产品咨询
* 询价标题:   
快捷提问: (不用打字 “快捷提问”帮您忙!)
* 主要内容:
我希望在 日前回复
公司名:
*联系人:
*联系电话:
电子邮箱:
QQ :
* 验证码:  
没有合适的产品?是否在线询价?
询价标题
联系人
电话
主要内容
验证码