联系我们
公司名称:浩瀚色谱(山东)应用技术开发有限公司
联系人:王经理
电话:0632-5667636
手机:15562228838(微信同号)13963221227(微信同号)
传真:0632-5667636
邮件:1404939462@qq.com
地址:山东省滕州市(市场部和技术部);
产品详情

产品简介
测定大气中甲烷、总烃及非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲苯,芝麻香白酒,3-甲硫基丙醇,乙酸乙酯,环氧乙烷,二甲醚...
产品详细介绍
测定大气中甲烷、总烃及非甲烷总烃
测定大气中甲烷、总烃及非甲烷总烃 详细信息:
滕州市浩瀚色谱仪器技术服务有限公司,采用六通阀进样,双毛细管柱、F单ID检测器气相色谱法,一次进样即可测得大气中的CH4、总烃及非甲烷总烃(NMHC)的测试数据.同时对色谱中FID检测器中出现的氧峰初步可认定为"干扰峰",在分析中可忽略不计.方法的检出限:CH40.03 mg/m3,总烃0.04 mg/m3,NMHC 0.06 mg/m3.变异系数:CH43.81%,总烃2.07%,NHMC 5.07%.加标回收率:CH496.1%,NHMC 96.1%~98%.
测定大气中甲烷、总烃及非甲烷总烃 图片:



Determination of methane, total hydrocarbons and non-methane total hydrocarbons in the atmosphere
Determination of methane, total hydrocarbons and non-methane total hydrocarbons in the atmosphere Details:
Statio nary phase: deactivated capillary column
Specification: 30m/0.53mm
Model: HH-THC
Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. uses six-port valve injection, double capillary column and F single ID detector gas chromatography to measure CH4, total hydrocarbons and non-methane total hydrocarbons in the atmosphere. NMHC) test data. At the same time, the oxygen peak appearing in the FID detector in the chromatogram can be initially identified as "interference peak", which is negligible in the analysis. The detection limit of the method: CH40.03 mg/m3, total hydrocarbon 0.04 Mg/m3, NMHC 0.06 mg/m3. Coefficient of variation: CH43.81%, total hydrocarbon 2.07%, NHMC 5.07%. Standard recovery: CH496.1%, NHMC 96.1%-98%.
Determination of methane, total hydrocarbons and non-methane total hydrocarbons in the atmosphere
如果您觉得“HH-THC-30总烃毛细管柱 测定大气中甲烷、总烃及非甲烷总烃”描述资料不够齐全,请联系我们获取详细资料。(联系时请告诉我从给览网看到的,我们将给您最大优惠!)
本页链接:http://www.geilan.com/com_haohanyiqi/sell/itemid-8670256.html
已经有1089位访客查看了本页.
测定大气中甲烷、总烃及非甲烷总烃 详细信息:
固定相:脱活毛细管柱
规格:30m/0.53mm
型号:HH-THC
滕州市浩瀚色谱仪器技术服务有限公司,采用六通阀进样,双毛细管柱、F单ID检测器气相色谱法,一次进样即可测得大气中的CH4、总烃及非甲烷总烃(NMHC)的测试数据.同时对色谱中FID检测器中出现的氧峰初步可认定为"干扰峰",在分析中可忽略不计.方法的检出限:CH40.03 mg/m3,总烃0.04 mg/m3,NMHC 0.06 mg/m3.变异系数:CH43.81%,总烃2.07%,NHMC 5.07%.加标回收率:CH496.1%,NHMC 96.1%~98%.
测定大气中甲烷、总烃及非甲烷总烃 图片:



Determination of methane, total hydrocarbons and non-methane total hydrocarbons in the atmosphere
Determination of methane, total hydrocarbons and non-methane total hydrocarbons in the atmosphere Details:
Statio
Specification: 30m/0.53mm
Model: HH-THC
Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. uses six-port valve injection, double capillary column and F single ID detector gas chromatography to measure CH4, total hydrocarbons and non-methane total hydrocarbons in the atmosphere. NMHC) test data. At the same time, the oxygen peak appearing in the FID detector in the chromatogram can be initially identified as "interference peak", which is negligible in the analysis. The detection limit of the method: CH40.03 mg/m3, total hydrocarbon 0.04 Mg/m3, NMHC 0.06 mg/m3. Coefficient of variation: CH43.81%, total hydrocarbon 2.07%, NHMC 5.07%. Standard recovery: CH496.1%, NHMC 96.1%-98%.
Determination of methane, total hydrocarbons and non-methane total hydrocarbons in the atmosphere
如果您觉得“HH-THC-30总烃毛细管柱 测定大气中甲烷、总烃及非甲烷总烃”描述资料不够齐全,请联系我们获取详细资料。(联系时请告诉我从给览网看到的,我们将给您最大优惠!)
本页链接:http://www.geilan.com/com_haohanyiqi/sell/itemid-8670256.html
已经有1089位访客查看了本页.
产品咨询
相关产品推荐
相关技术文章
- icon 热烈祝贺《高纯对二甲苯专用毛细管柱》成功上市
- icon 祝贺《HH-Formol 工业甲醛溶液分析专用毛细管柱
- icon 乙酸中微量甲酸测定专用毛细管柱研制成功
- icon 浩瀚色谱研制的《工业甲醇中微量甲醛测定专用毛
- icon 浩瀚色谱研制的HH-BXJ-V工业丙烯腈专用柱上市