PEG-20M毛细管柱 测定儿童防护口罩中环氧乙烷、环氧丙烷

  • 产品/服务:PEG-20M毛细管柱 测定儿童防护口罩中环氧乙烷、环氧丙烷
  • 型 号:PEG-20M毛细管柱
  • 品 牌:浩瀚色谱
  • 单 价:面议 
  • 更新日期:2022-02-08
  • 有效期至:长期有效
  • 浏览次数:935
  • 立即询价
产品简介

测定儿童防护口罩中环氧乙烷、环氧丙烷,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,增塑剂,塑化剂,过氧化物...

产品详细介绍
测定儿童防护口罩中环氧乙烷、环氧丙烷
测定儿童防护口罩中环氧乙烷、环氧丙烷 详细信息:

名称:毛细管柱
规格:30m*0.32mm*0.25um
型号:PEG-20M
应用: 吹扫捕集-气相色谱-串联质谱法测定儿童防护口罩中环氧乙烷、环氧丙烷

浩瀚色谱(山东)应用技术开发有限公司采用吹扫捕集–气相色谱–串联质谱(P&T–GC–MS/MS)技术了测定儿童防护口罩中环氧乙烷、环氧丙烷的方法。样品采用4%乙酸水溶液作为模拟液浸泡处理,浸泡液中目标物通过吹扫富集于捕集管中,热脱附后进入气相色谱,采用PEG-20M型色谱柱(30 m×0.32 mm,0.25μm)分离,气相色谱串联质谱多反应监控模式进行分析检测,内标法定量。环氧乙烷、环氧丙烷在质量浓度为0.2~15 ng/mL范围内与色谱峰面积线性关系良好,环氧乙烷、环氧丙烷的相关系数分别为0.999 8、0.997 5,方法定量限均为0.01 μg/g,满足GB/T 38880—2020及国外相关标准的限值要求。样品加标回收率为91.5%~115.7%,测定结果的相对标准偏差不大于4.9%(n=6)。该方法适用于儿童防护口罩中环氧乙烷、环氧丙烷消毒有效成分的批量测定。 


Determination of ethylene oxide and propylene oxide in children's protective masks
Determination of ethylene oxide and propylene oxide in children's protective masks Details:

Name: capillary column
Specifications: 30m*0.32mm*0.25um
Model: PEG-20M
Application: Determination of ethylene oxide and propylene oxide in children's protective masks by purge and trap-gas chromatography-tandem mass spectrometry

Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. used purge and trap-gas chromatography-tandem mass spectrometry (P&T-GC-MS/MS) technology to determine the method of ethylene oxide and propylene oxide in children's protective masks. The sample was soaked with 4% acetic acid aqueous solution as the simulated solution, the target compounds in the soaking solution were enriched in the trapping tube by purging, and then entered into the gas chromatography after thermal desorption. 0.25μm) separation, gas chromatography tandem mass spectrometry multiple reaction monitoring mode for analysis and detection, internal standard method for quantification. The linear relationship between ethylene oxide and propylene oxide and the chromatographic peak area was good in the mass concentration range of 0.2~15 ng/mL, and the correlation coefficients of ethylene oxide and propylene oxide were 0.999 8 and 0.997 5, respectively. Both are 0.01 μg/g, which meets the limit requirements of GB/T 38880-2020 and relevant foreign standards. The recoveries of samples spiked were 91.5%-115.7%, and the relative standard deviation of the determination results was not more than 4.9% (n=6). This method is suitable for batch determination of ethylene oxide and propylene oxide disinfection active ingredients in children's protective masks. 


如果您觉得“PEG-20M毛细管柱 测定儿童防护口罩中环氧乙烷、环氧丙烷”描述资料不够齐全,请联系我们获取详细资料。(联系时请告诉我从给览网看到的,我们将给您最大优惠!)
本页链接:http://www.geilan.com/com_haohansepu/sell/itemid-9235593.html
已经有935位访客查看了本页.
产品咨询
* 询价标题:   
快捷提问: (不用打字 “快捷提问”帮您忙!)
* 主要内容:
我希望在 日前回复
公司名:
*联系人:
*联系电话:
电子邮箱:
QQ :
* 验证码:  
高级版会员 第9年 认    证:企业信息已通过认证
主营业务:色谱仪器技术开发、技术推广技术咨询;销售:实验室设备。(依法须经批准的项目,经相关部门批准后凭许可证方可展经营活动)
联系方式

联系人:王晓莹

电话:0632-5667636

手机:15562228838(微信同号)13963221227(微信同号)

邮件:wangxiaoying9@126.com

联系时,请告知信息来自给览网

没有合适的产品?是否在线询价?
询价标题
联系人
电话
主要内容
验证码