浩瀚色谱(山东)应用技术开发有限公司

浩瀚色谱(山东)应用技术开发有限公司

[给览网认证,请放心拨打]
咨询
热线
0632-5667636
产品详情

2%OV-17/Chromosorb W填充柱 工作场所空气有毒物质测定硫化物CS2

  • 产品/服务:2%OV-17/Chromosorb W填充柱 工作场所空气有毒物质测定硫化物CS2
  • 型 号:2%OV-17/Chromosorb W填充柱
  • 品 牌:浩瀚色谱
  • 单 价:面议 
  • 更新日期:2021-11-26
  • 有效期至:长期有效
  • 浏览次数:1009
  • 立即询价
产品简介

工作场所空气有毒物质测定硫化物CS2,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,增塑剂,塑化剂,医疗器械...

产品详细介绍
工作场所空气有毒物质测定硫化物CS2
工作场所空气有毒物质测定硫化物CS2 详细信息:

名称:填充柱
规格:1.5m*4mm
型号:2%OV-17/Chromosorb W 60-80目
应用:GBZ/T 160.33-2004工作场所空气有毒物质测定 硫化物

为探讨我国粘胶作业工人的实际二硫化碳 (CS2 )接触水平以及现有的监测方法的代表性 ,浩瀚色谱(山东)应用技术开发有限公司应用国际上统一的采样分析方法对某粘胶长丝车间进行了车间空气中 CS2 浓度和 CS2 作业工人接触水平进行了测定 ,并对测定作业场所的 3种监测方法的代表性进行了评价.结果发现 ,用采样泵活性碳吸收管采样并以气相色谱分析法检测车间固定点 CS2 浓度为 :2 3.2 9± 1.35 m g/ m3,多功能气体分析仪测定结果为 12 .73m g/ m3,用个体采样法测得工人的实际接触水平为 :2 0 .0 5 mg/ m3.因而认为 :不宜以常用的车间内空气浓度来替代工人实际接触水平 ,因两者差异有统计学意义 (P<0 .0 1) ;建议工人实际接触水平应为个体采样法所测的结果或应以时间加权平均浓度表示为宜.

工作场所空气有毒物质测定硫化物CS2  测试谱图:



Determination of Toxic Substances in Workplace Air Sulfide CS2
Determination of Toxic Substances in Workplace Air Sulfide CS2 Details:

Name: Packed column
Specification: 1.5m*4mm
Model: 2%OV-17/Chromosorb W 60-80 mesh
Application: GBZ/T 160.33-2004 Determination of Toxic Substances in Workplace Air Sulfide

In order to explore the actual carbon disulfide (CS2) exposure level of Chinese viscose workers and the representativeness of existing monitoring methods, Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. applied an internationally unified sampling and analysis method to a viscose filament workshop The concentration of CS2 in the air in the workshop and the exposure level of CS2 workers were measured, and the representativeness of the three monitoring methods for measuring the workplace was evaluated. As a result, it was found that the sampling pump activated carbon absorber tube was used for sampling and analyzed by gas chromatography The concentration of CS2 at a fixed point in the workshop detected by the method is: 2 3.2 9± 1.35 mg/m3, the measurement result of the multi-function gas analyzer is 12.73 mg/m3, and the actual exposure level of the worker measured by the individual sampling method is: 20.0 5 mg/m3. Therefore, it is believed that it is not appropriate to replace the actual exposure level of workers with the commonly used air concentration in the workshop, because the difference between the two is statistically significant (P<0.01); it is recommended that the actual exposure level of workers should be the individual sampling method The measured result may be expressed as a time-weighted average concentration.

Test spectrum of sulfide CS2 for the determination of toxic substances in the workplace air: 



如果您觉得“2%OV-17/Chromosorb W填充柱 工作场所空气有毒物质测定硫化物CS2”描述资料不够齐全,请联系我们获取详细资料。(联系时请告诉我从给览网看到的,我们将给您最大优惠!)
本页链接:http://www.geilan.com/com_haohansepu/sell/itemid-9213324.html
已经有1009位访客查看了本页.
产品咨询
* 询价标题:   
快捷提问: (不用打字 “快捷提问”帮您忙!)
* 主要内容:
我希望在 日前回复
公司名:
*联系人:
*联系电话:
电子邮箱:
QQ :
* 验证码:  
高级版会员 第9年 认    证:企业信息已通过认证
主营业务:色谱仪器技术开发、技术推广技术咨询;销售:实验室设备。(依法须经批准的项目,经相关部门批准后凭许可证方可展经营活动)
联系方式

联系人:王晓莹

电话:0632-5667636

手机:15562228838(微信同号)13963221227(微信同号)

邮件:wangxiaoying9@126.com

联系时,请告知信息来自给览网

没有合适的产品?是否在线询价?
询价标题
联系人
电话
主要内容
验证码